Free evaluation No recovery, no charge Free shipping to the lab Temecula, CA and London, UK. Mail-in service across the US.

Dell RAID and server data recovery

PowerEdge servers on PERC controllers, PowerVault and EqualLogic arrays. When a virtual disk fails or goes offline, we recover the data behind it.

  • Free evaluation
  • No recovery, no charge
  • Free shipping to the lab

Fast, secure Dell RAID recovery

Dell PowerEdge is the most common server we see from small and medium-sized businesses. A RAID array gives protection that a single disk cannot, and it can still fail in ways that put the whole system at risk. That is when you need a knowledgeable and reliable RAID recovery company.

Dell systems we recover

PowerEdge rack and tower servers
Every generation, from the R710 and T610 era through R740, R750 and R760 to the current R770 family.
PERC controllers
H310, H330, H700, H710, H730, H740P, H745, H755 and H965, and the earlier PERC 5 and 6.
Software RAID and boot devices
PERC S-series software RAID and BOSS mirrored M.2 boot cards.
PowerVault
MD and ME direct-attached and SAN arrays.
EqualLogic PS and Compellent SC
Older iSCSI and Fibre Channel SANs with proprietary layouts.
Precision workstations
Intel RST and VROC arrays.

The most common Dell RAID failures

Virtual disk failed or offline
More drives have dropped than the RAID level allows.
Foreign configuration
After a controller swap or drives being reseated, the controller sees the array as foreign. Importing the wrong configuration, or clearing it, overwrites the array layout.
Punctured array
A rebuild copies an unreadable block from a second weak drive into the array. The damage survives every later rebuild.
Controller or cache failure
A failed PERC or cache battery loses writes that had not reached the disks.
Stalled rebuild
The array waits to rebuild and a failing disk stops it completing.
System does not boot
The array is intact and the operating system or datastore is corrupt.
Deleted files and corrupt databases
Logical loss on a healthy array.

Do not clear a foreign configuration, force drives online, or run a consistency check on a failed virtual disk. Power the server down and call us.

Dell models we recover, 2013 to 2026

Examples of the model numbers we see most often, grouped by the years each range was sold. The model is on the front bezel and the pull-out service tag at the front of the chassis; the PERC model shows in the Ctrl+R / F2 controller setup.

YearsRangeModel numbers
2010–2018PowerVault MD arraysMD1200, MD1220, MD3200, MD3200i, MD1400, MD3400, MD3420
2011–2019EqualLogic PS SeriesPS4100, PS6100, PS4210, PS6210
2012–2014PowerEdge 12th generationPERC H310 / H710 / H710PR320, R420, R520, R620, R720, R720xd, T420, T620
2012–2017PERC 8 and PERC 9 controllersPERC H310, PERC H710, PERC H710P, PERC H810, PERC H330, PERC H730, PERC H730P, PERC H830
2014–2017PowerEdge 13th generationPERC H330 / H730 / H730PR430, R530, R630, R730, R730xd, T330, T430, T630
2017–2021PowerEdge 14th generationPERC H330 / H730P / H740PR340, R440, R540, R640, R740, R740xd, T440, T640
2017–2026PERC 10, 11 and 12 controllers, and PERC H975iPERC H740P, PERC H840, PERC H345, PERC H745, PERC H755, PERC H965i, PERC H975i
2018–2026PowerVault ME4 and ME5ME4012, ME4024, ME4084, ME5012, ME5024, ME5084
2021–2023PowerEdge 15th generationPERC H345 / H745 / H755R250, R350, R450, R550, R650, R750, R750xs, T550
2023–2025PowerEdge 16th generationPERC H965iR260, R360, R660, R760, R760xs, T160, T360, T560
2025–2026PowerEdge 17th generationPERC H965i / H975iR470, R570, R670, R770, R6715, R7715

Not listed? These are examples, not limits. If your model is missing we almost certainly still recover it. Give us the number when you start a case.

Contact RMLD for your Dell RAID recovery

Our server recovery lab in Temecula, California is equipped for both logical and physical recovery. We stock donor drives for the SAS and SATA disks used in PowerEdge servers and repair physically failed members before imaging them. The array is then rebuilt virtually and your VMware, Hyper-V or Windows Server data extracted and checked.

Call RMLD on (951) 595-8065 for advice or to discuss your Dell RAID recovery, or start a case online.

How a case works

Six steps from the first call to your files. You approve the quote and check the results before paying.

  1. Tell us what happenedCall or start a case online. A technician reviews it and tells you how to send or bring the device.
  2. Ship it or drop it offShipping to the lab is free. You can also hand it in at Temecula or London.
  3. Free evaluationWe diagnose the fault and send a firm quote. Nothing is charged for this.
  4. Recovery in our labOnce you approve, the work is done in-house. Your device never leaves our company.
  5. You check the filesYou receive a list of what was recovered and confirm it before paying.
  6. Data returnedOn a new drive, your own drive, or by encrypted download. No recovery means no charge.

Talk to a technician before you try anything else

The evaluation is free, and the first advice you get can decide whether the data comes back.

CallStart a case