Fast, secure Dell RAID recovery
Dell PowerEdge is the most common server we see from small and medium-sized businesses. A RAID array gives protection that a single disk cannot, and it can still fail in ways that put the whole system at risk. That is when you need a knowledgeable and reliable RAID recovery company.
Dell systems we recover
- PowerEdge rack and tower servers
- Every generation, from the R710 and T610 era through R740, R750 and R760 to the current R770 family.
- PERC controllers
- H310, H330, H700, H710, H730, H740P, H745, H755 and H965, and the earlier PERC 5 and 6.
- Software RAID and boot devices
- PERC S-series software RAID and BOSS mirrored M.2 boot cards.
- PowerVault
- MD and ME direct-attached and SAN arrays.
- EqualLogic PS and Compellent SC
- Older iSCSI and Fibre Channel SANs with proprietary layouts.
- Precision workstations
- Intel RST and VROC arrays.
The most common Dell RAID failures
- Virtual disk failed or offline
- More drives have dropped than the RAID level allows.
- Foreign configuration
- After a controller swap or drives being reseated, the controller sees the array as foreign. Importing the wrong configuration, or clearing it, overwrites the array layout.
- Punctured array
- A rebuild copies an unreadable block from a second weak drive into the array. The damage survives every later rebuild.
- Controller or cache failure
- A failed PERC or cache battery loses writes that had not reached the disks.
- Stalled rebuild
- The array waits to rebuild and a failing disk stops it completing.
- System does not boot
- The array is intact and the operating system or datastore is corrupt.
- Deleted files and corrupt databases
- Logical loss on a healthy array.
Do not clear a foreign configuration, force drives online, or run a consistency check on a failed virtual disk. Power the server down and call us.
Dell models we recover, 2013 to 2026
Examples of the model numbers we see most often, grouped by the years each range was sold. The model is on the front bezel and the pull-out service tag at the front of the chassis; the PERC model shows in the Ctrl+R / F2 controller setup.
| Years | Range | Model numbers |
|---|---|---|
| 2010–2018 | PowerVault MD arrays | MD1200, MD1220, MD3200, MD3200i, MD1400, MD3400, MD3420 |
| 2011–2019 | EqualLogic PS Series | PS4100, PS6100, PS4210, PS6210 |
| 2012–2014 | PowerEdge 12th generationPERC H310 / H710 / H710P | R320, R420, R520, R620, R720, R720xd, T420, T620 |
| 2012–2017 | PERC 8 and PERC 9 controllers | PERC H310, PERC H710, PERC H710P, PERC H810, PERC H330, PERC H730, PERC H730P, PERC H830 |
| 2014–2017 | PowerEdge 13th generationPERC H330 / H730 / H730P | R430, R530, R630, R730, R730xd, T330, T430, T630 |
| 2017–2021 | PowerEdge 14th generationPERC H330 / H730P / H740P | R340, R440, R540, R640, R740, R740xd, T440, T640 |
| 2017–2026 | PERC 10, 11 and 12 controllers, and PERC H975i | PERC H740P, PERC H840, PERC H345, PERC H745, PERC H755, PERC H965i, PERC H975i |
| 2018–2026 | PowerVault ME4 and ME5 | ME4012, ME4024, ME4084, ME5012, ME5024, ME5084 |
| 2021–2023 | PowerEdge 15th generationPERC H345 / H745 / H755 | R250, R350, R450, R550, R650, R750, R750xs, T550 |
| 2023–2025 | PowerEdge 16th generationPERC H965i | R260, R360, R660, R760, R760xs, T160, T360, T560 |
| 2025–2026 | PowerEdge 17th generationPERC H965i / H975i | R470, R570, R670, R770, R6715, R7715 |
Not listed? These are examples, not limits. If your model is missing we almost certainly still recover it. Give us the number when you start a case.
Contact RMLD for your Dell RAID recovery
Our server recovery lab in Temecula, California is equipped for both logical and physical recovery. We stock donor drives for the SAS and SATA disks used in PowerEdge servers and repair physically failed members before imaging them. The array is then rebuilt virtually and your VMware, Hyper-V or Windows Server data extracted and checked.
Call RMLD on (951) 595-8065 for advice or to discuss your Dell RAID recovery, or start a case online.